Loopshore Sensors

Technical Reference

Overview

This document lists all sensors used in Loopshore devices across Gen 1 and Gen 2 hardware revisions, with the operating range each manufacturer states in its datasheet.

The device keeps running outside a sensor’s operating range, but that sensor’s readings are not reliable there. This matters most in cold spaces and for outdoor installations (outdoors, the device must be protected from rain and snow while letting outside air flow freely around it). Loop One and the other devices operate from −20 °C to +40 °C, but below 0 °C the CO2 sensor does not measure, and VOC and particulate matter measurement are limited. See the Outdoor installation section of each product’s user manual.

Sensors Common to Both Generations

Sensor Measurement Operating range (manufacturer) Notes Datasheet
Senseair Sunrise CO2 concentration (NDIR) 0 … +50 °C, 0–85 %RH non-condensing Does not operate below 0 °C. Standard accuracy at +15 … +35 °C. Product specification
Sensirion SPS30 Particulate matter (PM1.0, PM2.5, PM4.0, PM10) −10 … +60 °C, 0–95 %RH Best performance at +10 … +40 °C and 20–80 %RH. Datasheet
Silicon Labs Si1151 Ambient light (lux) −40 … +85 °C Datasheet
ST LIS3DH Acceleration (X/Y/Z), motion detection −40 … +85 °C Datasheet
TDK ICS-43434 Sound pressure level (dB) −40 … +85 °C Datasheet
Nordic nRF9160 (GNSS) GPS position, altitude, speed, heading −40 … +85 °C Product specification

Gen 1 Sensors

Sensors used exclusively in Gen 1 devices. These were replaced in Gen 2.

Sensor Measurement Operating range (manufacturer) Notes Datasheet
Bosch BMP280 Barometric pressure, temperature −40 … +85 °C Full accuracy at 0 … +65 °C. Datasheet
TI HDC2080 Temperature, relative humidity Temperature −40 … +125 °C, humidity −20 … +70 °C, non-condensing Prolonged operation above 80 %RH can shift the reading. Datasheet
Sensirion SGPC3 Total VOC (tVOC) +5 … +55 °C and 4–30 g/m³ absolute humidity, non-condensing Does not operate in sub-zero air. Datasheet

Gen 2 Sensors

Sensors introduced in Gen 2, either as replacements for Gen 1 parts or as new additions.

Replacements:

Sensor Replaces Measurement Operating range (manufacturer) Notes Datasheet
Bosch BMP581 BMP280 Barometric pressure, temperature −40 … +85 °C Datasheet
Sensirion SHT45 (SHT4x) HDC2080 Temperature, relative humidity −40 … +125 °C, 0–100 %RH Humidity most accurate at +5 … +60 °C and 20–80 %RH. Rated for condensing conditions. Datasheet
Renesas ZMOD4410 SGPC3 Total VOC, indoor air quality (IAQ) −40 … +65 °C (algorithm), 0–90 %RH non-condensing Best accuracy at 0 … +40 °C. Sensitive to low absolute humidity. Datasheet
Sensirion SGP41 (alternative) SGPC3 VOC Index (1–500), NOx −10 … +50 °C, 0–90 %RH non-condensing Humidity compensation optimised for dew points −13 … +31 °C. Datasheet

New additions:

Sensor Measurement Operating range (manufacturer) Notes Datasheet
Sensirion SDP8xx Differential pressure (Pa) −40 … +85 °C, non-condensing Temperature compensation −20 … +85 °C. Datasheet
TI ADS122C04 External temperature via PT100 RTD (24-bit ADC) −40 … +125 °C The probe’s own range depends on the probe type. Datasheet
Analog Devices DS18B20 Temperature (1-Wire) −55 … +125 °C ±0.5 °C at −10 … +85 °C. Datasheet
Analog Devices MAX31888 Temperature, high precision (1-Wire) −40 … +125 °C ±0.25 °C at −20 … +105 °C. Datasheet

Battery

Component Operating range (manufacturer) Notes
Li-Ion cell, 3.63 V / 4900 mAh Discharge −20 … +60 °C, charge 0 … +45 °C At −10 °C the cell delivers about 70 % of its nominal capacity. The device does not charge the battery below 0 °C.

Notes


Loopshore Oy — loopshore.com